Dual Pilot Goes Wrong
  • Case Study of Line Relay Protection

    Case Study of Line Relay Protection

    Abstract—This case study presents the working, testing and commissioning of the 220 kV backup distance protection schemes employed on the Pipri West Grid of Karachi Electric Limited (KEL). Different disturbances in power system could affect relay behavior and may result in relay misoperation or unintended operation.


  • Is the optical fiber cable for line optical difference protection single-mode or multi-mode

    Is the optical fiber cable for line optical difference protection single-mode or multi-mode

    Single Mode fibers are identified by the designation OS or Optical Single-mode Fiber. Multimode Fiber comparison, I will compare those two fiber optic cables, helping you learn the difference and determine which best suits your fiber cabling system. Choosing between single mode and multi mode fiber depends on your specific requirements for distance, bandwidth, and budget. But not all fiber cables are created equal: multimode (MM) and single mode (SM) fibers are the two primary types.


  • Case Study of Gabon IDC Data Center Construction

    Case Study of Gabon IDC Data Center Construction

    This intervention concerns the feasibility studies of the Gabon Component of the Central African Fibre Optic Backbone (CAB) project. It includes the setting up of a National Data Centre (Datacenter), a Computer Attack Warning and Response Centre (CSIRT) and a public key. Gabon is set to position itself as a rising digital hub in Central Africa with the launch of construction on a state-of-the-art national data centre. The project, entrusted to leading infrastructure firm PORTEO S. Cybastion will work. Last Thursday, June 29, Gabon's Minister of Digital Economy, Jean Pierre Doukaga Kassa, and the CEO of the Indian company Shapoorji-Pallonji, Ransit Gajave, signed a memorandum of understanding for the construction of a national data center in Gabon. The national data center project has been underway for several months with the company first visiting Gabon in March 2023, but is.

    [PDF Version]
  • Maldives Data Center Telecom Shelter Construction Case Study

    Maldives Data Center Telecom Shelter Construction Case Study

    Qatari telecoms company Ooredoo has launched a new data center in the Hulhumalé smart city in the Maldives. The facility is built to Tier III standards, but not yet certified. The Maldives, known for its breathtaking islands and vibrant tourism industry, is rapidly embracing technological advancements, including the development of state-of-the-art data centers. The inauguration ceremony was jointly. The Republic of the Maldives, a Small Island Developing State (SIDS), consists of some 1'200 widely dispersed islands that are spread over 820 kilometers from North to South. Given the country's unique geographical characteristics, it is a noteworthy that the country achieved universal access in. The project involves partially funding Dhiraagu's investment capital expenditures (CAPEX) and working capital requirements. The proposed CAPEX will enhance connectivity and improve telecoms services in Maldives. These comprise data center expansion, service extension and coverage enhancement, and. Received a Token of Appreciation from the Government of Maldives for achieving 100% Fibre-to-the-Home (FTTH) coverage across all inhabited islands in the Maldives.

    [PDF Version]
  • Line Relay Protection Simulation

    Line Relay Protection Simulation

    This project simulates an impedance-type distance relay for protecting a 220 kV transmission line using MATLAB/Simulink. The relay detects faults by measuring line impedance and operates in three zones (Z1, Z2, Z3) with configurable time delays. All the details of substation protection and control system (P&C). Gridscale X Advanced Protection Assessment, formerly known as PSS® CAPE, gives protection engineers access to the world's largest library of highly detailed relay models – with more than 7,300 relay styles, reclosers and fuses. A Fourier block estimates the fundamental voltage and current signals. Many line relays will also apply to specific end of the branch. When a relay type requires the assignment of a specific end of the branch, there will be a field Device Location which can be set to. ABB's Control Room offering includes a comprehensive range of solutions designed to optimize the operator workspace for critical 24/7 processes across various industries. The control room is considered one of the most critical areas in any facility, impacting daily decision-making and overall.

    [PDF Version]
  • Relay protection configuration for the line

    Relay protection configuration for the line

    A three-stage configuration is commonly used: Stage I: Instantaneous zero-sequence current protection, covering 70%–80% of the line length. So, in this case, to protect the whole line, the setting has to be able to detect fault current above 150 A. This document gives the model setting calculations, line protection r other power system elements like transformer, shunt reactor and bus bar. Protective relays and devices have been developed over 100 years ago to provide “lastline”of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions.