  • Low-loss high-frequency switching power supplies for industrial Ethernet

    Low-loss high-frequency switching power supplies for industrial Ethernet

    SiC (Silicon Carbide) and GaN (Gallium Nitride) devices offer higher breakdown voltage, lower losses, and faster switching, enabling MHz-level operation and 30–50% lower losses. Integrated driver circuits (IPMs) simplify design and improve reliability. Advanced TopologiesThe AC-DC converter is an interleaved bridgeless totem pole (ILTP) stage featuring two phases that provide power factor correction (PFC) and limits total harmonic distortion (THD). A low-pass filter using non-dissipative passive components such as inductors. A switching power supply (often abbreviated SMPS for switched-mode power supply) is an electronic power converter known for efficiently transforming AC power into stable DC voltage through rapid switching techniques. Soft-switching technologies, which reduce switching losses and electromagnetic interference, are at the core of this transformation. At. This article will explore the basic points to design a general power supply across a frequency axis that has been sorted from low to high frequencies. Humans are able to hear frequencies between 20Hz and 20kHz.

    [PDF Version]
  • Relay protection characteristic curve

    Relay protection characteristic curve

    The time current characteristic curve in overcurrent relay is one of the most important tools used to understand how a protection relay behaves when fault current flows through a power system. This curve shows the relationship between the magnitude of current and the operating time of. After a circuit is de-energized by a circuit protective device, the circuit protective device, the circuit may not be manually reenergized until it has been determined that the equipment and circuit can be safely energized.


  • Getting Closer to Relay Protection

    Getting Closer to Relay Protection

    Relay protection technology plays a vital role in fault detection, isolation, and recovery, evolving with intelligent algorithms, digital equipment, and automated coordination to enhance grid reliability. As technology advances and grids become smarter, the tools used to test and maintain these systems, such as the relay test set, are evolving to meet new challenges. This article explores the. The global energy transition is ushering in a new era of power electronic-dominated grids (PEDGs), to complement the increase in the widespread integration of renewable sources like wind and solar. This paper explores the development of relay protection technology in smart grids, analyzing. Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor technology protect staff and plant facilities for many years.

    [PDF Version]
  • What does kd represent in relay protection

    What does kd represent in relay protection

    The type KD relay is a polyphase compensator type relay which provides a single zone of phase protection for all three phases. It provides instantaneous tripping for all combinations of phase-to-phase faults, two-phase-to-ground faults, and three-phase faults. The second section is connected to a potentiometer and a fixed loading re-sistor and provides a. One connection uses an auxiliary 5:5 ratio The main contact of KD-10 and KD-11 relays will current transformer to insert the -31 component. Page 4 X-Y-Z triangle also tends to be zero un- produce restraining torque. A memory circuit in the KD-10 For a fault at B, the currents.